03.Input Switch Change

Function

The external control equipment switches the input of the plasma monitor. Transmission Data

DFH 80H 60H 47H 01H

DATA00 CKS

 

DATA00 : Input Select

01H : Video1

 

02H

: Video2

 

03H

: Video3

 

05H

: HD (HD1 or DTV or DTV1)

 

06H

: HD2(DTV2 or SCART1/SCART2)

 

07H

: RGB1 / PC1

 

08H

: RGB2 / PC2

 

0CH : RGB3 / PC3

 

0DH : HD3(SCART3)

ACK

The plasma monitor returns the following ACK when the input is switched.

3FH 60H 80H 47H 00H CKS

15