15. GREEN Gain Data
Function
The external control equipment changes the GREEN Gain Data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00 : USER PICTURE Gain Flag | 01H |
|
DATA01 : GREEN Gain Flag | 02H |
|
DATA02 : GREEN Gain1(Bias) | D8H : | |
| : |
|
| FFH : | |
| 00H | : 0 |
| 01H | : +01 |
| : |
|
| 1EH : +30 | |
DATA03: GREEN Gain2(Drive) | D8H : | |
| : |
|
| FFH : | |
| 00H | : 0 |
| 01H | : +01 |
|
| : |
| 1EH : +30 | |
ACK |
|
|
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag | 01H |
DATA01: GREEN Gain Flag | 02H |
22