181
MVP MANUAL
(19) Model fresh [F command]
Input : Fh1h2
Explanation :• Sets back to the model data preset at shipment.
Model data No.
h1h2
0 0 Auto
0 1 VGA (640 x 480)
0 2 IBM-PC (EGA emulation)
0 3 Macintosh 13-inch monitor mode (Standard)
0 4 Macintosh 13-inch monitor mode (RasterOps type)
0 5 Macintosh 13-inch monitor mode (Power Mac)
0 6 FM-R50
0 7 IBM Think Pad 230C
0 8 X68000
0 9 NEC PC9801 (640 x 400 mode)
10
Unused area (Do not specify using the M command.)
27
28
User preset area
58
9 9 Models other than above.
This model data can be locked only using the M command.
The data range which can be preset by the user is 28 to 58. 28 to 58 contains the VGA data (same
as 01) at shipment.
Refer to Mode 99 mentioned later for details of model No. 99.
(20) Measurement data display [FRQ command]
Input : FRQ
Explanation :• Displays the horizontal frequency, vertical frequency, and full line number of the personal com-
puter connected to the MVP currently. Use as reference when inputting the data of models whose
details are unknown.
(Example)
: FRQ
fH=24 kHz, fV=56.4 Hz, 1V=440 LINE.