ReadiVoice Administration & Maintenance Guide
122 Proprietary & Confidential
— Routed System: The Traditional Shared, Traditional Private, and
Two Passcode Private call flow options are available. Voyant has
tested and supports only the combinations shown in Table5-3.
6Select Yes or No for the Validate on Acc Code option. This option isn’t
available if Routing Mode is Non-Routed System Private.
— Yes: The ReadiVoice system identifies a caller’s conference using the
access code only.
—No: The ReadiVoice system identifies a caller’s conference using the
DNIS/access code pair.
7To implement your changes, click Commit Configuration.
The system confirms your changes and provides a link back to the System
Configuration page. If necessary, a note reminds you that you must
restart the application.
8Click the link to return to the System Configuration page and verify that
the settings are correct.
9If you changed any of the routing or call flow options, you must run the
tnl_mkln
script:
aLog into the CACS as root and, in an XTerm window, enter
tcsh
.
bChange to the
/rahome/bin
directory.
cRun the make link script by entering
tnl_mkln
.
dOne at a time, reboot the bridge(s).
Especially for InnoVox4000 bridges, it’s important to wait until a
bridge finishes booting before rebooting the next bridge.
10 If necessary, restart the ReadiVoice application (see “Stopping and
Restarting ReadiVoice Processes” on page111).
Table 5-3 Supported call flows on routed systems
Call Flow Options Translation Number Type
Traditional Shared Random
Two Password Private Fixed Translation Number
Traditional Shared +
Two Password Private
Fixed Translation Number with
3-digit code