
 Customizing SoundStructure Designs
5 - 63
meter and the text box next to the AGC meter.
The range of the AGC can be adjusted by expanding the AGC control and 
adjusting the maximum and minimum gains. By default the maximum and 
minimum gain are set to 6 and -6 respectively on microphone and telephony 
signals.
The maximum AGC value specifies the maximum amount of gain the AGC can 
apply to increase the input signal level as the AGC tries to reach the Sound-
Structure nominal signal level.
The minimum AGC value specifies the maximum amount of attenuation the 
AGC can apply to attenuate the input signal as the AGC tries to reach the 
SoundStructure nominal signal level.
Dynamics
The output dynamics processing available on the outputs is the same as the 
input dynamics processing and is described in the input channel processing 
section of this chapter.
Equalization
The equalization processing that is available for both the telephone input and 
output signals consists of a dedicated
•Low Pass,
•High Pass,
•Low Shelf,
•High Shelf, and
•10 parametric equalizers
as shown in the following figure. The telephone input and output can be con-