8in.

(203mm)

7 in.

the vent pipe. Use the two sheet metal screws provided to connect the strips to the pipe section (Figure 5.9).

(178mm)

7 in.

(178mm)

6 in.

(152mm)

Figure 5.7

1/4 in. (6mm)

FOLD STRAP

HERE

SHEET METAL SCREW

WALL THIMBLE COVER/CEILING FIRESTOP AS REQUIRED BY LOCAL JURISDICTION

WALL

THIMBLE

STRAP

(NOTE: If you are installing termination cap HHW2, the pipe will be off center on flashing). Ensure that proper clearances to combustible materials are maintained. If you are using an approved termination cap other than HHW2 (part #841-0670) on a building with vinyl siding, a vinyl siding standoff should be installed between the termination cap and the exterior wall (Figure 5.8). Follow manufacturer’s instructions for attaching the vinyl siding standoff to the horizontal termination cap. The vinyl siding standoff prevents excessive heat from possibly melting the vinyl siding material. The vent terminal cap shall not be recessed into a wall or siding. Remove siding from the area where the standoff will be located.

 

 

VINYL SIDING

 

 

APPLY SEALANT TO ALL

 

 

FOUR SIDES

 

 

SCREWS

 

 

BOLT HORIZONTAL TOP

 

 

TO VINYL STANDOFF

WALL THIMBLE

 

SCREWS

 

 

COVER

 

VINYL SIDING STANDOFF

 

 

 

WALL THIMBLE

WITH SIDING BENEATH

 

REMOVED

 

 

Figure 5.8

Step 5.

Place the wall thimble cover over the pipe assembly and slide the appliance and vent assembly towards the wall, carefully inserting the vent pipe into the vent termination cap assembly. It is important that the vent pipe extend into the vent termination cap a sufficient distance so as to result in a minimum pipe overlap of 1-1/4 in. (32mm). Secure the connection between the vent pipe and the vent termination cap by attaching the two sheet metal strips extending from the vent termination cap assembly into the outer wall of

Figure 5.9

Note: The attachment from the vent pipe to the vent termination cap must be sealed with silicone. Termination caps shall not be recessed into a wall or siding.

WARNING

Fire Hazard.

Exhaust Fume Risk.

Impaired Performance of Appliance.

Ensure vent components are locked together correctly.

Pipe may separate if not properly joined.

WARNING

Do NOT connect a pipe section to a termination cap without using the telescoping flue section found on the termination cap.

WARNING

Burn Risk.

Local codes may require installation of a cap shield to prevent anything or anyone from touching the hot cap.

 

 

 

 