PART 2 - SECTION II - OPERATING INSTRUCTIONS

MODELS WHICH ARE CONNECTED TO A MICROZONE SYSTEM

If the heater(s) are operated by a Microzone system, there will be a rotary type control knob fitted which should be aligned to the desired temperature.

HIGH LIMIT SWITCH.

ALL heaters are fitted with a manual reset high limit switch. This control will shut down the heater in the event of a fault with the temperature control and/or overheat of the system.

This setting will vary, depending on the type of system being used but must not be too close to the operating temperature, as nuisance tripping will occur.

The usual setting is approximately 60 - 65 ºC

To set the Honeywell L6188C High Limit, remove Philips Head screw next to red reset button, remove lighter grey cover, pull out darker grey top cover to reveal adjustment.

WATER TREATMENT

For your health and the protection of your pool equipment it is absolutely essential that your pool water is chemically balanced.

WARRANTY PROCEDURE FOR WATER LEAKS FROM HEAT EXCHANGER.

CORROSIVE WATER

VOIDS ALL

WARRANTIES!

1.The service technician inspects the tube bundle, if the water leak is through one or more pinholes (usually caused by corrosion) then the warranty is voided and therefore any repairs will be paid for by the owner.

2.If the service technician deems that the water leak is not caused by corrosion, the

technician can replace the faulty parts at the technician’s risk. Raypak will supply the new components, the service technician will pay all charges and then there may be a refund when the parts have been returned to Raypak and we have agreed that the warranty is applicable.

3.If there is an objection to this policy, we suggest that the faulty components be submitted to an independent testing facility for analysis, at the customer’s expense. If the testing facility deems that the leaking was caused by a manufacturing defect, on production of the official report and details of costs, Raypak will refund all relevant expenses incurred by the customer.

14