Electrical Characteristics Ta = 25°C Ta = –40 to 85°C
Item Symbol VCC (V) Min Typ Max Min Typ Max Unit Test Conditions
3.0 to 3.6 — — — 1.5 — —
VIH 4.5 to 5.5 — — — 2.0 — —
3.0 to 3.6 — — — — — 0.6
Input voltage
VIL 4.5 to 5.5 — — — — — 0.8
V Control input only
3.3 — — — — 0.10 —
Hysteresis
voltage VH 5.0 — — — — 0.15 — V VT+ – VT–
3.0 — 50 150 — — 190
On-state switch
resistance RON 4.5 — 40 75 — — 100
Ω VIN = VCC or GND
VC = VIH
IT = 1 mA
3.0 — 100 180 — — 225
Peak on
resistance RON (P) 4.5 — 50 100 — — 125
Ω VIN = VCC to GND
VC = VIH
IT = 1 mA
Off-state switch
leakage current Is (OFF) 5.5 — — ±0.1 — — ±1.0 µA VIN = VCC, VOUT = GND
or VIN = GND,
VO = VCC, VC = VIL
On-state switch
leakage current Is (ON) 5.5 — — ±0.1 — — ±1.0 µA VIN = VCC or GND
VC = VIH
Input current IIN 0 to 5.5 — — ±0.1 — — ±1.0 µA VIN = 5.5 V or GND
ICC 5.5 — — — — — 10 µA VIN = VCC or GND
Quiescent
supply current ∆ICC 5.5 — — — — — 1.5 mA VIN = 3.4 V
Control input
capacitance CIC — — 3.5 — — — — pF
Switch terminal
capacitance CIN / OUT — — 4.0 — — — — pF
Feed through
capacitance CIN–OUT — — 0.5 — — — — pF
• VCC = 3.3 ± 0.3 V
Ta = 25°C Ta = –40 to 85°C
Item Symbol
Min Typ Max Min Max Unit Test
Conditions FROM
(Input) TO
(Output)
— 1.5 6.0 — 10.0 CL = 15 pF
Propagation
delay time tPLH
tPHL — 4.0 9.0 — 12.0 ns CL = 50 pF
IN/OUT
or OUT/IN
OUT/IN
or IN/OUT
— 4.0 11.0 — 15.0 CL = 15 pF
Enable time tZH
tZL — 6.0 18.0 — 22.0 ns CL = 50 pF C IN/OUT
or OUT/IN
— 5.0 11.0 — 15.0 CL = 15 pF
Disable time tHZ
tLZ — 8.0 18.0 — 22.0 ns CL = 50 pF C IN/OUT
or OUT/IN
• VCC = 5.0 ± 0.5 V
Ta = 25°C Ta = –40 to 85°C
Item Symbol
Min Typ Max Min Max Unit Test
Conditions FROM
(Input) TO
(Output)
— 1.0 4.0 — 7.0 CL = 15 pF
Propagation
delay time tPLH
tPHL — 3.0 6.0 — 8.0 ns CL = 50 pF
IN/OUT
or OUT/IN
OUT/IN
or IN/OUT
— 3.0 7.0 — 10.0 CL = 15 pF
Enable time tZH
tZL — 5.0 12.0 — 16.0 ns CL = 50 pF C IN/OUT
or OUT/IN
— 4.0 7.0 — 10.0 CL = 15 pF
Disable time tHZ
tLZ — 6.0 12.0 — 16.0 ns CL = 50 pF C IN/OUT
or OUT/IN