
HD74LV2GT04A
Rev.2.00, Oct.14.2003, page 4 of 7
Recommended Operating ConditionsItem Symbol Min Max Unit Conditions
Supply voltage range VCC 3.0 5.5 V
Input voltage range VI05.5V
Output voltage range VO0V
CC V
—6 V
CC = 3.0 to 3.6 VIOL
—12 V
CC = 4.5 to 5.5 V
—–6 V
CC = 3.0 to 3.6 V
Output current
IOH
— –12
mA
VCC = 4.5 to 5.5 V
0 100 VCC = 3.0 to 3.6 VInput transition rise or fall rate ∆t / ∆v
020
ns / V
VCC = 4.5 to 5.5 V
Operating free-air temperature Ta–40 85 °C
Note: Unused or floating inputs must be held high or low.
Electrical Characteristic• Ta = –40 to 85°C
Item Symbol VCC (V) * Min Typ Max Unit Test condition
3.0 to 3.6 1.5 — —VIH
4.5 to 5.5 2.0 — —
3.0 to 3.6 — — 0.6
Input voltage
VIL
4.5 to 5.5 — — 0.8
V
3.3 — 0.10 —Hysteresis voltage VH
5.0 — 0.15 —
VV
T+ – VT–
Min to Max VCC–0.1 — — IOH = –50 µA
3.0 2.48 — — IOH = –6 mA
VOH
4.5 3.8 — — IOH = –12 mA
Min to Max — — 0.1 IOL = 50 µA
3.0 — — 0.44 IOL = 6 mA
Output voltage
VOL
4.5 — — 0.55
V
IOL = 12 mA
Input current IIN 0 to 5.5 — — ±1 µAV
IN = 5.5 V or GND
Quiescent
supply current ICC 5.5 — — 10 µAV
IN = VCC or GND,
IO = 0
∆ICC 5.5 — — 1.5 mA One input VIN = 3.4 V,
other input VCC or GND
Output leakage current IOFF 0——5µAV
I or VO = 0 to 5.5 V
Input capacitance CIN 5.0 — 3.0 — pF VIN = VCC or GND
Note: For conditions shown as Min or Max, use the appropriate values under recommended operating
conditions.