29733 R2 06/01/2003
18

TABLE A-1 BECKETT AFG OIL BURNER SET-UP

BECKETT AFG SERIES OIL BURNERS
FURNACE
MODEL
OUTPUT
BTU/Hr
BURNER
MODEL NOZZLE PUMP
PRESSURE
FLOW
RATE HEAD STATIC
PLATE
80F (060) 58,100 1, 2 AF76BO 0.50 / 70° W 100 PSIG 0.50 GPH F0 3-3/8 in.
80F (070) 68,000 2 AF76BN 0.65 / 70° W 100 PSIG 0.65 GPH F3 3-3/8 in.
80F (080) 78,900 2 AF76BN 0.70 / 70° W 100 PSIG 0.70 GPH F3 3-3/8 in.
120F (090) 87,700 2 AF76BZHS 0.75 / 70° W 100 PSIG 0.75 GPH F4 3-3/8 in.
120F (100) 98,800 AF76BZHS 0.85 / 70° W 100 PSIG 0.85 GPH F4 3-3/8 in.
120F (120) 113,400 AF76BZHS 1.00 / 70° W 100 PSIG 1.00 GPH F4 3-3/8 in.
1 F0 Head required for proper combustion. 2 Low Firing Rate Baffle required, Beckett Part No. 3708
In the United States, the R. W. Beckett “AFG” Burner may be equipped with Beckett’s “Inlet Air Shut-Off”, Beckett Part No. AF/A 5861, to increase efficiency. It
reduces the amount of air passing through the oil burner, combustion chamber, breeching, etc. up the chimney between burner cycles.
NOTE: THE USE OF THIS CONTROL CAN OCCASIONALLY CAUSE POST COMBUSTION NOZZLE DRIP.

TABLE A-2 RIELLO 40F OIL BURNER SET-UP

RIELLO 40 F SERIES OIL BURNERS
FURNACE
MODEL
OUTPUT
BTU/Hr
BURNER
MODEL NOZZLE PUMP
PRESSURE
FLOW
RATE HEAD STATIC
PLATE
80F (060) 58,000 40 F3 0.40 / 60° W 160 PSIG 0.50 GPH 1.5 2.25
80F (070) 73,000 40 F3 0.50 / 60° W 150 PSIG 0.60 GPH 1.5 2.5
80F (080) 79,000 40 F3 0.60 / 60° W 145 PSIG 0.70 GPH 2.0 3.0
120F (090) 87,000 40 F3 0.75 / 70° W 150 PSIG 0.75 GPH 2.0 3.52
120F (100) 100,000 40 F3 0.85 / 70° W 150 PSIG 0.85 GPH 2.5 4.0
120F (120) 118,000 40 F3 1.00 / 70° W 160 PSIG 0.95 GPH 3.0 6.0
Appendix A
HO-B DATA