49
Preparations
1
1 Preparations
Safety Lock
Function
PC can be used to turn the Safety Lock function on or off on a product.
This control is available regardless of whether or not the power is turned on.
Viewing the safety lock state (Get Safety Lock Status)
Enabling or disabling safety lock (Set Safety Lock Enable / Disable)
"Safety Lock": Safety lock code to be set on a product
1 : ON
0 : OFF
Ack
"Safety Lock": Safety lock code to be set on a product
Nak
"ERR" : A code showing what error has occurred
Header Command
ID
Data length
Checksum
0xAA 0x5D 0
Header Command
ID
Data length Data
Checksu
m
0xAA 0x5D 1 "Safety
Lock"
Header Comma
nd
ID
Data length Ack/Nak r-CMD Val1
Checksu
m
0xAA 0xFF 3 ‘A’ 0x5D "Safety
Lock"
Header Comma
nd ID
Data length Ack/Nak r-CMD Val1 Checksu
m
0xAA 0xFF 3 ‘N’ 0x5D "ERR"