Power Cable | Remote Control/ 1 Batteries |
Cleaning Cloth | |
| (Not available in all locations) |
Sold separately
LED Indications |
|
| ||
●:Light is On ◐:Light is Blinking | ○:Light is Off | |||
STAND | LAMP | TEMP | Information | |
BY | ||||
|
|
| ||
● | ○ | ○ | If you press the POWER button on the remote control or projector, the screen | |
appears within 30 seconds. | ||||
|
|
| ||
● | ● | ○ | The projector is in normal operating condition. | |
● | ◐ | ○ | This state appears when the projector is preparing an operation after the POWER button | |
on the projector or the remote control has been pressed. | ||||
|
|
| ||
|
|
| The POWER button is pressed to turn off the projector, and the cooling system is in | |
○ | ◐ | ○ | operation to cool off the inside of the projector. (Lasts for about 1 minute and 30 | |
|
|
| seconds) | |
◐ | ○ | ◐ | Refer to Action 1 below if the cooling fan inside the projector is not in normal operation | |
condition. | ||||
|
|
| ||
○ | ◐ | ◐ | Refer to Action 2 below if the lamp cover protecting the lamp unit is not closed | |
properly. | ||||
|
|
| ||
○ | ○ | ◐ | Power is turned off automatically when temperature inside of the projector goes beyond | |
the control limit. Refer to Action 3. | ||||
|
|
| ||
● | ◐ | ◐ | A problem has occurred when operating the DDP IC in the product. Refer to Action 4. | |
◐ | ◐ | ◐ | A problem has occurred with the operation of the lamp. Refer to Action 5. | |
● | ◐ | ● | The lifetime of the lamp has expired. Refer to Action 6. | |
◐ | ◐ | ○ | The memory in the product is not operating normally. Contact a service center. | |
◐ | ◐ | ● | The power for the product is not operating normally. Contact a service center. | |
◐ | ● | ◐ | A problem has occurred when operating the color wheel in the product. Refer to Action | |
4. | ||||
|
|
|
Clearing Indicator Problems
Classification | State | Measures |