Power Cable

Remote Control/ 1 Batteries

Cleaning Cloth

 

(Not available in all locations)

Sold separately

D-Sub Cable

LED Indications

 

 

●:Light is On :Light is Blinking

○:Light is Off

STAND

LAMP

TEMP

Information

BY

 

 

 

If you press the POWER button on the remote control or projector, the screen

appears within 30 seconds.

 

 

 

The projector is in normal operating condition.

This state appears when the projector is preparing an operation after the POWER button

on the projector or the remote control has been pressed.

 

 

 

 

 

 

The POWER button is pressed to turn off the projector, and the cooling system is in

operation to cool off the inside of the projector. (Lasts for about 1 minute and 30

 

 

 

seconds)

Refer to Action 1 below if the cooling fan inside the projector is not in normal operation

condition.

 

 

 

Refer to Action 2 below if the lamp cover protecting the lamp unit is not closed

properly.

 

 

 

Power is turned off automatically when temperature inside of the projector goes beyond

the control limit. Refer to Action 3.

 

 

 

A problem has occurred when operating the DDP IC in the product. Refer to Action 4.

A problem has occurred with the operation of the lamp. Refer to Action 5.

The lifetime of the lamp has expired. Refer to Action 6.

The memory in the product is not operating normally. Contact a service center.

The power for the product is not operating normally. Contact a service center.

A problem has occurred when operating the color wheel in the product. Refer to Action

4.

 

 

 

Clearing Indicator Problems

Classification

State

Measures