(1)The platform should be higher than the maximum. snow depth. (Fig. 2-5)

(2)The two anchoring feet of the outdoor unit should be attached to the platform, and the platform should be installed beneath the air-intake side of the outdoor unit.

(3)The platform foundation must be solid and the unit must be secured with anchor bolts.

(4)When installing on a roof subject to strong wind, countermeasures must be taken to prevent the unit from being overturned.

Dimensions of Snow / Wind-proof Ducting and Refrigerant Tubing Space for Installation

 

 

 

Min. 4"

 

 

Duct

12"

 

Duct

Outdoor Unit

 

Min. 4"

12"

Unit: inch

 

 

 

 

1117_C_I

1. Specifications

In regions with snow fall, the outdoor unit should be provided with a platform and snow-proof duct.

Without snow-

Snow-proof

 

proof ducting

ducting

 

(Low platform)

(High platform)

 

 

0937_C_I

 

Fig. 2-5

Fig. 2-6

1

 

 

Outdoor

 

 

Unit

 

 

Duct

Duct

Higher than the maximum snow depth

Air

Air

Intake

Intake

 

 

Platform (foundation)

About 1/2 of the unit height

0488_C_I

Fig. 2-7