4.2PARALLEL INTERFACE

1. Data input timing

DATA0 to 7

T3

T1 T2

STROBE

T4

BUSY

T5

T6 T7

ACK

 

Min.

Max.

Unit

T1

0.1

s

T2

0.5

s

T3

0.5

s

T4

0.5

s

T5

0

s

T6

0.5

s

T7

1.0

s

4.3SERIAL INTERFACE

1.Hardware control

The RTS signal (Low or High) controls the transmission of the data from a host computer.

When the data stored in the input buffer of the printer exceeds 4,046 bytes, the RTS signal turns Low.

Once the RTS signal turns Low, the host computer stops to transmit the data.

If the data stored in the input buffer of the printer falls below 3,995 bytes, the RTS signal turns High.

Once the RTS signal turns High, the host computer resumes transmitting the rest of the data.

When the printer fails (for example, paper-out), the RTS signal also turns Low. And then, after the printer gets back to normal, the RTS signal turns High.

4-3