6. Advanced Functions

1.Memory function

This meter can store up to nine measured values in memory for incident light and reflected light simultaneously. This feature can be used in the following modes;

Ambient light : shutter speed priority, aperture priority or EV mode.

Electronic Flash light : cord, cordless or wireless flash radio triggering mode.

1.Press the Measuring button and take a mea- surement. The Current measured value on the ana- log scale will blink.

2.Press the Memory button and store the mea- sured value in memory, and the memorized value on the analog scale will stop blinking.

The number of values in memory is displayed on the LCD. The memorized value is displayed on the analog scale. By repeating this operation, up to nine values can be stored in memory.

3.To clear the memory, press the memory clear but- ton @3or switch to another measurement mode.

Reference:

When pressing Memory clear button @3once, the last memorized value is cleared. If you want to clear all memorized values, please hold down the Mode button and press the Memory clear button.

Memory button

Number of memorized value

Set shuttter speed

1/10 f stop

Measured f stop

Memorized f stop

4.Memory Recall

To enter Memory recall mode, hold down the Mode button and press the Memory button, and the "M" icon and number of stored measurements will blink. Rotate Jog wheel to recall memo- rized value. To exit Memory recall mode, hold down the Mode button and press the Memory button again, and "M" icon and number of stored measurements will stop blinking.

Reference:

During Memory recall mode, when you press Memory clear button, the currently recalled value is cleared.

NOTE:

The memory function cannot be used in “Multiple flash (cumulative) mode.”

Measured values for ten times or more measurements will be displayed but cannot be stored in memory.

-31-