Operating Modes and Options 
Remote Power On/Off offers three exclusive Operating Modes with several selectable options for each mode.  Operating modes and 
options are determined by the Power On/Off +Aux control unit's DIP-switch settings. 
The two common Operating Modes are the Power-ON Mode (next page) and the REBOOT Mode (begins page 20).  These operating 
modes, their individual options, and the DIP-switch settings, are discussed in the following sections.  Discussion of the third mode, the 
Infinite-On/Off Mode, begins on page 26. 
Safeguards: 
The Power On/Off +Aux control unit is programmed with several safeguards which apply automatically to each operating 
mode.  It is important to note each as they may cause time-related functions to appear incorrect. 
Wake-up Delay - Whenever power is first supplied to the Power On/Off +Aux control unit there will be a 30 second 
delay before any power-ON signal is sent to the IPM.  This delay can help protect the devices attached to the IPM from 
power surges and transient spikes that occur during brownouts or following a blackout. 
Minimum ON Time - In all cases where the power is automatically turned-ON by a function of the Power On/Off +Aux 
unit, it will remain ON for a minimum of one (1) minute for a PP02, 90 seconds for a PP03, and five (5) minutes for a 
PPNT.  This design is to ensure a complete POST (Power On Self Test), RAM check, and complete boot whenever the 
PC is powered-ON. 
Minimum OFF Time - Anytime the power is turned-OFF by an automatic function of the Power On/Off +Aux unit, it 
will remain OFF for a minimum of 30 seconds.  This design is to ensure a complete "settle" whenever the PC is powered-
OFF. 
REBOOT Inhibit Time - This timer inhibits incoming calls from initiating a reboot for  21/2 minutes whenever power is 
first supplied, the IPM is instructed to turn on, or following a prior REBOOT.  This guarantees the host or server system is 
always allowed to fully boot and be ready to answer incoming calls before subsequent reboots are allowed; perpetual 
reboots due to incoming calls that cannot be answered - because the system is still booting - are avoided.   This safeguard, 
designed for high-traffic systems such as fax servers, applies only to the REBOOT Operating Mode.  After supplying 
power to the Power On/Off +Aux unit for the first time, be sure to wait about three minutes before testing. 
Remote Power On/Off    Operating Modes  •  15