Async Bank 0 Config W/R Addr.: 0x7000_0010 Default: 0x3FFF_FFF2
Async Bank 1 Config W/R Addr.: 0x7000_0014 Default: 0x3FFF_FFF2
Async Bank 2 Config W/R Addr.: 0x7000_0018 Default: 0x3FFF_FFF2
Async Bank 3 Config W/R Addr.: 0x7000_001C Default: 0x3FFF_FFF2
Description Setting of timing and data bus width for access via asynchronous interface CS_PER0_N -
CS_PER3_N. (The AHB clock is 20 ns in length)
Bit No. Name Description
31 EWS_XAS Extend Wait Timing Mode
0: RDY_PER_N = asynchronous
1: RDY_PER_N = synchronous
30 EW Extend Wait mode
0: RDY_PER_N = don’t care
1: Wait until RDY_PER_N is active
29..26 W_SU Write strobe setup cycles
(w_su + 1) AHB clock cycles between valid address, data, and chip select
and falling edge of the write signal.
25..20 W_STROBE Write strobe duration cycles
(w_strobe + 1) AHB clock cycles between falling and rising edges of the write
signal.
19..17 W_HOLD Write strobe hold cycles
(w_hold + 1) AHB clock cycles between rising edge of the write signal and
change of address, data, and chip select.
16..13 R_SU Read strobe setup cycles
(r_su + 1) AHB clock cycles between valid address and chip select and
falling edge of the read signal (RD_N).
12..7 R_STROBE Read strobe duration cycles
(r_strobe + 1) AHB clock cycles between falling and rising edges of the read
signal.
6..4 R_HOLD Read strobe hold cycles
(r_hold + 1) AHB clock cycles between rising edge of the read signal and
change of address and chip select.
3..2 Reserved Reserved
1..0 ASIZE Asynchronous bank size
00: 8-bit data bus
01: 16-bit data bus
1x: 32-bit data bus
Copyright © Siemens AG 2007. All rights reserved. 72 ERTEC 200 Manual