20mm or more
Connector cover

Pressure Sensor

Operation Manual

PSE530 Series

Thank you for purchasing the SMC PSE530 Series Pressure Sensor.

Please read this manual carefully before operating pressure sensor and understand pressure sensor, its capabilities and limitations. Please keep this manual handy for future reference.

URL http://www.smcworld.com
Installation (addendum information)
Attaching the connector to the lead wire
Sensor wire is stripped as shown in the right figure.The Insulation of the corresponding color shown in the following table is
put into the pin of the number stamped

 

Insulation
on the connector for sensor connection to the bottom.
Pin No.Color of Insulation

 

 

1

Brown (DC (+) )

 

 

2

N.C.

 

 

3

Blue (DC (-) )

 

 

4

Black (IN:1 to 5VDC)

 

A

 

 

 

 

 

2

1

It checks that the above-mentioned preparation

 

3

 

4

 

work has been performed correctly, and A part shown in right figure is pushed by hand and makes temporary connection.

A part center is straightly pushed in by tools, such as pliers.

Re-use cannot be performed once it connects the connector for sensor connection completely.

A sensor connector cannot be taken apart for reuse once it is crimped.If the wire arrangement is incorrect or if the wire insertion fails,

use a new sensor connector. 1 2 34When connecting the connector to
PSE200/PSE300 series, please use

 

 

the connector for Sensor Lead Wire(ZS-28-C) oras below.
MakerModel No.
(c)Sumitomo 3M37104-3101-000FL
Tyco Electronics AMP

3-1473562-4

OMRONXN2A-1430
Please contact with each connector maker about catalogue.
Connector
Connector Connecting / Disconnecting

When connecting the connector, insert it straight onto the pin holding the lever and connector body between fingers and lock the connector by pushing the lever claw into the square groove in the housing until connector clicks.

When disconnecting the connector, push down the lever by thumb to disengage the lever claw from the square groove. Then pull the connector straight out.

PSE200 SeriesPSE300 Series

 

 

 

 

 

 

Lever

 

Lever

 

Connector for Sensor

 

 

 

 

 

 

Lead Wire

 

 

Example of Internal Circuit and Wiring
Output Specification

 

 

 

Voltage output :

 

 

 

Brown DC (+)

 

 

1 to 5V

 

circuit1kΩ

 

 

 

Output impedance :Black OUT

 

 

 

 

 

 

 

 

 

Approx. 1kΩ

 

Main

 

(Analog output)

-

DC

 

 

 

 

 

+

12 to 24V

 

 

 

 

Blue DC (-)

 

 

Outline with Dimensions (in mm)

PSE53

-M5

 

 

 

 

 

 

 

 

3.4

 

 

 

 

M5

0.8

 

 

 

 

29.4

 

Pressure port

 

 

 

 

 

 

 

 

 

 

 

 

 

27.2

 

 

2

.

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

5.4

 

 

12

7.2

 

 

 

 

 

 

 

 

 

 

3

 

12

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

5

5.5

 

 

 

 

PSE53

- R06

 

 

 

 

 

 

 

 

R07

 

 

 

 

 

 

 

 

 

 

 

45.5

 

 

Pressure port

3.4

 

 

43.3

 

 

5.4

 

 

12

7.2

 

 

D

 

 

 

Model No.Applicable port size(D)

 

 

 

 

 

 

PSE53

-R06

6mm

 

 

 

 

 

 

PSE53

-R07

1/4inch

 

 

 

 

 

When connect cable for sensor

 

 

 

 

 

 

 

 

 

9.8

 

 

 

 

 

 

 

10.4

2.7

 

 

 

 

 

SAFETY

The Pressure Sensor and this manual contain essential information for the protection of users and others from possible injury and property damage and to ensure correct handling.

Please check that you fully understand the definition of the following messages (signs) before going on to read the text, and always follow the instructions.

IMPORTANT MESSAGES

Read this manual and follow its instructions. Signal words such as WARNING and NOTE will be followed by important safety information that must be carefully reviewed.

Indicates a potentially hazardous situation which could result in death or serious injury if you do not follow instructions.

WARNING

Do not disassemble, remodel ( including change of printed circuit board ) or repair.

An injury or failure can result.Do not operate beyond specification range.Fire, malfunction or sensor damage can result.Do not operate in a combustible gas or explosive gas atmosphere.Fire or an explosion can result.This pressure sensor is not an explosion proof type.
OPERATOR

This operation manual has been written for those who have knowledge of machinery and apparatus that use pneumatic equipment and have full knowledge of assembly, operation and maintenance of such equipment.

Please read this operation manual carefully and understand it before assembling, operating or providing maintenance service to the pressure sensor.

NOTE

Follow the instructions given below when handling your pressure sensor. Otherwise, the sensor may be damaged or may fail, thereby resulting in malfunction.

Do not drop it, bring it into collision with other objects or apply excessive shock (980m/s2 or more).

Do not pull the lead wire with force nor lift the main unit by holding the lead wire. (Pulling strength less than 23N)

Do not insert wire nor other article into the pressure port. Perform wiring and cable correctly.

Do not perform wire or cable while power is on.Do not wire with the same circuit of power line or high-voltage line.

Connect Terminal FG to the ground when using a switching regulator obtained on the commercial market.

Keeping from water and dust, set an air tube to the safety area.
How to connect the cable for sensor.(Optional)

Pick with fingers the hemale connector of cable for sensor. Insert it paying attention of connector direction.

SensorMale connectorFemale connector

Cable for sensor have connector cover in order to prevent fall of female connector. Paying attention for connector cover direction, install on the sensor, rotate clockwise, and lock it.

To remove cable for sensor, rotate the connector cover anti- clockwise, relese lock, and remove connector cover.

After removing connector cover, pick with female connector with fingers and pull out.

Lock

Sensor

Connector cover

Unlock
Specification
Model No.

 

PSE530-PSE531-PSE532-PSE533-
Rated pressure range0 to 101MPa0 to -101kPa0 to 101kPa-101 to 101kPa

 

 

 

 

 

 

 

Withstand pressure1.5MPa

 

500kPa

 

 

 

 

 

 

 

 

Fluid

 

Air, Non-corrosive gases, Incombustible gases

 

 

 

 

 

 

 

Power supply

12 to 24VDC, ripple(p-p)10% or less (Protection against inverse connection)

 

 

 

 

 

 

 

Current consumption

 

15mA or less

 

 

 

 

 

 

 

 

AnalogVoltageVoltage: 1 to 5V±2%F.S. or less (Rated pressure range)
output

output

Linearity : ±1%F.S. or less Output impedance : Approx.1kΩ

 

 

 

 

 

 

 

Repeatability

 

±1%F.S. or less

 

 

 

 

 

 

 

 

Effect form power supply

±1%F.S. or less with standard of analog output at 18V in the range of 12 to 24VDC

 

 

 

 

 

 

 

Temperature Characteristic±2%F.S. or less (25reference

 

 

 

 

 

 

 

 

Enclosure

 

IP40

 

 

 

 

 

 

 

 

EnvironmentAmbiebt temperatureOperation : 0 to 50,Storage :-10 to 70(No condensation, No freezing)

 

 

 

 

 

 

Withstand voltage

10 to 500Hz smaller one 1.5mm or 98m/s2

double amplitude, 2 hours each in direction

 

1000VAC, 50/60Hz, 1minute (Between lead block and case)

 

Insulation resistance

5MΩ or more 500VDC (Between lead block and case)

 

Vibration proof

 

of X, Y and Z

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Impact proof980m/s2 3times each in directions of X ,Y and Z respectively
Standard

 

 

CE MARKING

 

 

 

 

 

 

 

 

Cable

 

Halogen free heavy insulation cable, φ2.7, 0.15mm2, 3wire, 3m
Piping Specification

Model No.

M5

R06

 

R07

 

 

 

 

 

 

Port size

M5×0.8

φ6 Reducer

 

1/4inch Reducer

 

 

 

 

 

MaterialSensor pressure sensing part : Silicon O-ring : NBR

 

 

 

 

 

 

Body : SUS303Body : PBT

 

 

 

 

 

 

WeightWith cable(3m)

41g

 

38g

 

 

 

 

 

Excluding cable

7g

 

3.8g