OPERATING INSTRUCTIONS

STEP 3

Connecting the remote control cable

4

5

6

7

2.6

Insert the protective cover into the lock housing during use of the device.

Check the control cable and source assembly connectors using the NO GO gauge according to the daily inspection section.

Remove the protective rubber cap from the remote control connector.

Slide the remote control connector assembly's collar back and open the jaws to expose the male portion of the control cable connector

(i.e. the ball-end on the control cable connector).

Press back the spring-loaded locking pin of

the source assembly connector with a thumb-nail and engage the male and female portions of the connectors.

Release the locking pin of the source assembly connector and check that the connection is secure.

Use the NO GO gauge to check the gap between the joined connectors during the daily inspection.