4.1 Adjustment of minimum for natural gas

Instructions for the installer

4.1 Adjustment of minimum for natural gas

Light the burner and take it to the minimum 4.2 Regulation of minimum for LPG. Remove the gas tap knob and turn the adjustment screw inside or at the side of the tap shaft (depending on the model) until there is a regular minimum flame. Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). Repeat the operation on all the gas taps.

4.2 Regulation of minimum for LPG

To regulate the minimum for LPG, completely tighten (clockwise) the screw inside or next to the gas tap pin (depending on the model).

The diameters of the by-passes for each burner are given in table “3.2 Burner and nozzle characteristics table”.

4.3 Positioning and levelling of the appliance

Having carried out the electricity and gas hook-up, level the appliance using the four adjustable legs.

4.4Mounting the rear top upstand

Position the upstand above the top, taking care to align holes A with holes B.

Secure the upstand to the top by tightening screws C.