Sony DFW-X700, DFW-SX900 CSR F0F0060Ch, CSR F0F00614h Isochronous Transmission Start/Stop

Models: DFW-SX900 DFW-X700

1 50
Download 50 pages 50.92 Kb
Page 24
Image 24

DFW-SX900

DFW-X700

SETTINGS OF CAMERA CONTROL AND STATUS REGISTER

CSR F0F0060Ch

Isochronous Channel, Transmit Speed

Specify Isochronous Channel (0 – 0Fh), Transmit Speed (200M, 400M bps).

SpeedCommand

---------------------------------------------------

1 (200M bps)

n1000000h

2 (400M bps)

n2000000h

n: Isochronous Channel 0 – Fh

NOTE : Set when CSR F0F00614h Iso_EN is OFF (STOP).

The minimum Transmit Speed which can be selected differs according to Video Format, Video Mode, and Frame Rate. Set according to the following table.

DFW-SX900

Frame Rate

 

Format0

Format1

 

Format2

 

 

 

 

 

 

 

mode1

 

mode3

mode0

 

mode3

mode0

 

 

 

 

 

 

 

 

 

 

 

3.75

200M bps

 

200M bps

200M bps

 

200M bps

200M bps

 

 

 

 

 

 

 

 

7.5

200M bps

 

200M bps

200M bps

 

200M bps

400M bps

 

 

 

 

 

 

 

 

DFW-X700

Frame Rate

 

Format0

 

Format1

 

 

 

 

 

 

mode1

 

mode3

mode0

 

mode3

 

 

 

 

 

 

 

 

 

 

7.5

200M bps

 

200M bps

200M bps

 

200M bps

 

 

 

 

 

 

 

15

200M bps

 

200M bps

200M bps

 

400M bps

 

 

 

 

 

 

 

CSR F0F00614h Isochronous Transmission Start/Stop

Set the Start/Stop of image transmission by Isochronous.

Start : Command = 80000000h

Stop : Command = 00000000h

NOTE : Before setting Start of image transmission, set the CSR F0F00600h – F0F0060Ch.

22