Perform the Resume clear when all adjustments completed.
Resume clear setting method
1. Select the manual mode of the test mode, and set item number
043 (see page 13).
2. Press the Xkey.
3. Press the xkey to return to the test mode (display check
mode).
Patch Data Rewriting When Nonvolatile Memorywas Replaced
On this set, if the nonvolatile memory was replaced, the modified
program data must be written to the nonvolatile memory.
In such a case, write the modified data that meets the
microcomputer version following the procedure provided below.
Modified data writing method (version 1.000)
1. Select the manual mode of the test mode, and set item number
022 (see page 13).
2. Press the Xkey to initialize the patch data.
(The modified data writing is over, if the adjusted value changes
to DD)
3. Press the Nkey or >key to set item number 023.
4. Press the [VOL+] key once to change the adjusted value to 01.
5. Press the [DISPLAY] key on the remote commander for several
seconds (about 3 seconds) to activate the patch data write mode.
(The following display will appear where 00 is blinking)
6. Adjust with the [VOL+] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
16.
7. Press the Xkey.
(0FF8 is blinking)
8. Press the [VOL+] key once to change the blinking portion to
0FF9.
9. Press the xkey.
(00 is blinking)
10. Adjust with the [VOL+] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
0E.
11. Press the Xkey.
(0FF9 is blinking)
12. Press the [VOL+] key once to change the blinking portion to
0FFA.
13. Press the xkey.
(00 is blinking)
14. Adjust with the [VOL+] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
03.
15. Press the Xkey.
(0FFA is blinking)
16. Press the [VOL+] key five times to change the blinking por-
tion to 0FFF.
17. Press the xkey.
(00 is blinking)
18. Adjust with the [VOL+] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
DF.
19. Press the Xkey.
(0FFF is blinking)
20. Press the [VOL+] key once to change the blinking portion to
1000.

043 Resume CC

Remote commander LCD display
043 Res***
043 ResClr
Remote commander LCD display
Resume clear complete

023 Patch00

Remote commander LCD display
00
: Adjusted value

023 0FF800

Remote commander LCD display
00
: Adjusted value

023 0FF816

Remote commander LCD display
16
: Adjusted value

023 0FF900

Remote commander LCD display
00
: Adjusted value
023 0FF90E
Remote commander LCD display
0E
: Adjusted value

023 0FFA00

Remote commander LCD display
00
: Adjusted value

023 0FFA03

Remote commander LCD display
03
: Adjusted value

023 0FFF00

Remote commander LCD display
00
: Adjusted value

023 0FFFDF

Remote commander LCD display
DF
: Adjusted value
022 PatClr CC
Remote commander LCD display
022 ***SDD
Remote commander LCD display
DD
: Adjusted value
023 100000
Remote commander LCD display
00
: Adjusted value