Activity Detection (AD)

Select this check box to send an E-mail when an alarm triggered by the activity detection is output. You can set the time and the frame rate to save images to be attached to the E-mail in the boxes below.

Setting example: To save images during the period of time between 2 seconds before and 2 seconds after the alarm, with a frame rate of 3 fps.

Pre-Alarm Time: Select from the drop-down list the time in seconds you want to save images before an alarm output. (0 to 5 seconds can be set.)

Pre-Alarm Frame Rate: Select from the drop-down list the frame rate with which you want to save images before an alarm output. (1 to 5 fps can be set.) Post-Alarm Time: Select from the drop-down list the time in seconds you want to save images after an alarm output. (0 to 5 seconds can be set.)

Post-Alarm Frame Rate: Select from the drop-down list the frame rate with which you want to save images after an alarm output. (1 to 5 fps can be set.)

Sensor Input (SI)

Select this check box to send an E-mail when an alarm triggered by the sensor input is output. You can set the time and the frame rate to save images to be attached to the E-mail in the boxes below.

Pre-Alarm Time: Select from the drop-down list the time in seconds you want to save images before an alarm output. (0 to 5 seconds can be set.)

Pre-Alarm Frame Rate: Select from the drop-down list the frame rate with which you want to save images before an alarm output. (1 to 5 fps can be set.) Post-Alarm Time: Select from the drop-down list the time in seconds you want to save images after an alarm output. (0 to 5 seconds can be set.)

Post-Alarm Frame Rate: Select from the drop-down list the frame rate with which you want to save images after an alarm output. (1 to 5 fps can be set.)

Periodic Sending (PS)

Select this check box to send E-mails with images attached periodically regardless of alarm output.

Setting example: To send an E-mail with images attached every hour

Interval: Type the interval at which you want to send E- mails in the boxes. You can set the hour (H) between 0 and 168, and the minutes (M) between 0 and 55 in units of 5 minutes.

Image Size

Displays the size of the image to be attached to an E- mail. It is fixed to 360 × 243 for the SNC-VL10N, or

360× 288 for the SNC-VL10P.

Naming Method

Set the form of naming the image file to be attached to an E-mail. Select the check box(es) you want to add to the file name.

Date & Time Suffix

Adds the date and time to the file name.

Alarm Sensor

Adds the alarm mode to the file name.

AD: if the image is sent at the time of an alarm triggered by the activity detection.

SI: if the image is sent at the time of an alarm triggered by the sensor input.

PS: if the image is sent by Periodic Sending.

SEQ suffix

Adds consecutive numbers, 000 to 999, to the file name. The number is reset to 000 when you click Apply on the SMTP Setting page.

Manual Assigned Name

Type the file name up to 36 characters.

Suffix

Displays an extension “.eye.” The image is always sent in the Wavelet compressed format and “.eye” is added to its file name.

The example of a display

An example of the form you have set is displayed when you click Apply.

Subject Message Box

Type the title of the E-mail up to 64 characters.

Body Message Box

Type the text of the E-mail up to 255 characters.

Apply/Cancel/Help

See “Buttons common to every setting page” on page 14.

Note

When the images are sent by the E-mail function, the Frame Rate may not reach the set value depending on the network conditions and alarm frequency.

22 Sending Images via E-mail at Alarm — SMTP Setting Page