Activity Detection Threshold

Select the sensitivity of activity detection: Low, Mid, High, Super or Hyper.

The highest sensitivity is given by Hyper, which can detect the smallest movement.

Showing Pop-up

You can set for displaying “AD” (Activity Detection) pop-up on the lower-right of the monitor image when an alarm output is detected.

Select On to show a pop-up, or Off not to show it.

Notes

To show the pop-up on the Firewall Viewer, check on Show in the Caption menu when you are using the Firewall Viewer. (See “Caption” on page 10.)

The pop-up is not displayed when the Java Applet Viewer is used.

Output 1

Set up Output 1 of the Sensor I/O port.

Output 1 can output an alarm triggered by the activity detection or manually.

Output Status Control

Select Active to keep Output 1 of the Sensor I/O port usually open and short-circuit it only when an alarm is output. Select De-Activeto keep Output 1 usually short-circuited and open it only when an alarm is ouput.

Alarm Event-Based Output Activation Function Select AD to synchronize the output from Output 1 of the Sensor I/O port with an alarm by the activity detection, or Manual to output manually by clicking the Sensor 1 button on the viewer page.

Output Active Duration Time

Type the duration of the output from Output 1 between 1 and 60 seconds.

Lower Half of Sensor I/O Setting Page

Sensor Input (SI)

Set up the sensor input, that is, the input to the Sensor I/ O port on the rear panel of the camera.

Available Alarm Events

Select Enable if you want to output an alarm when the input to the Sensor I/O port is detected, or Disable if you do not want to output an alarm.

Scheduling

Using the boxes below, you can set up to 6 schedules on which the sensor input works.

Select Enable to enable all the schedules whose check boxes you have selected, or Disable to disable them.

Scheduling 1 to Scheduling 6

For each schedule, type the time in hours and minutes when the sensor input starts and ends, and select the check box(es) of the working days of the week.

To enable each schedule you have set, select the check box on the left of Scheduling. You can select multiple schedules.

Note

A schedule across days (ex. 22:00 - 2:00) cannot be set.

Sensor-Type Selection for Input

Select the level of the input which can be used to trigger an alarm: Low or High.

Input Current Status

Displays the current status of the device connected to the input of the Sensor I/O port.

26 Configuring the Sensor I/O Port — Sensor I/O Setting Page