Notes
•When you control the camera via the serial port using the VISCA protocol, match the communication settings with those on the connected controller.
•This camera does not support the daisy chain connection of VISCA devices. Connect the camera and the controller one for one.
TCP port No.When you select TCP on the Mode menu, type the port number for the TCP port (TCP Generic Driver). Set a port number other than
Select the communication baud rate for the peripheral device connected to the serial interface. You can select from among the following baud rates:
38400, 19200, 9600, 4800, 2400, 1200, 600, 300 (bps)
Parity bitSelect the parity bit for the peripheral device connected to the serial interface: None, Odd or Even.
Character lengthSelect the character length for the peripheral device connected to the serial interface: 7 or 8 (bits).
Stop bitsSelect the stop bit for the peripheral device connected to the serial interface: 1 or 2 (bits).
OK/Cancel
When you click Schedule on the Administrator menu, the Schedule setting page appears.
Use this page to set up to six schedules used for the Day/ Night function, FTP client function, SMTP function, Alarm out 1 or 2 function and Image memory function.
Schedule No. 1 to Schedule No. 6For each schedule, specify Start time (hour and minutes) and End time (hour and minutes), and check the days of the week that you want to activate the function.
OK/Cancel
Camera the Administrating
Setting the Schedule — Schedule setting Page / Setting the Schedule — Schedule setting Page | 43 |
|
|