M4557 - Model 9210 Nitriding Controller

IP Address Mask 3

255

IP Address Mask 4

0

IP Address Gateway 1

192

IP Address Gateway 2

168

IP Address Gateway 3

1

IP Address Gateway 4

1

 

 

Highlighting the parameter that needs to be entered and pressing the Enter button displays a numeric keypad that can be used to enter the required value. This will range from 0 to 256.

The default IP address is: 192.168.0.200

The default IP Address Gateway is: 192.168.1.1

Pressing the Esc key returns you to the configuration menu.

Event Control

This menu option will allow the user to set up the event control for the 9210. The “Hold Instrument Number” selection will display a numeric keypad that can range from 0 to 11. The “Hold Minimum PV” selection will display a numeric keypad that will range from 0 to 4000. The “Hold Maximum PV” selection will display a numeric keypad that will range from 0 to 4000. The “Event for Program Run” selection will display a numeric keypad that will range from –1to 15. A value of – 1 means there is no event. The “Event for Program Reset” selection will display a numeric keypad that will range from –1to 15. A value of – 1 means there is no event. The “Event 0” through “Event 15” selection will allow the user to assign the specific events. The list of options for this

selection is:

Event Inactive

Event Active, Open Triggers Hold

Event Active, Closed Triggers Hold

Valve Configuration

This screen provides setup information for the 9210 on the flow controller boards.

The “Decimal Place” selection determines how the 9210 will display gas flows. This will display a numeric keypad that can range from 0 to 4.

The “Valve Control Mode” selection determines how the 9210 will adjust gas flows if required for %Dissociation. This will display a screen that will allow the user to select the mode. The choices are:

Individual Trim

Flow

Ratio

Auto

The “D.A. Switch Point” selection determines the

control switch point for switching the atmosphere display from %Dissociation to Kn. This will display a

SSi Manual SERIES 9210-M4557-Nitriding

Page 32 of 32