ADDENDUM
The
A. Pump Hose Removal
WARNING
DISCONNECT THE FREEZER FROM ELECTRICAL SUPPLY SOURCE BEFORE SERVICING!
1.Remove the two phillips head screws from the rear panel and pull the rear panel down and out.
2.Disconnect the pump hose at the stainless steel and plastic fittings.
3.Loosen the square head screw on the impeller and slide the impeller off the shaft.
4.Remove the three slotted head screws and lock washers from the pump head and remove the pump head in one piece. (Fig. 1)
Three Screws
Figure 1.
5.Separate the two halves of the pump head and remove the hose.
6.Thoroughly clean the pump head in warm, soapy water.
B.Pump Hose Replacement
1.Assemble the two halves together and install the three slotted head screws and washers through the pump head. Install the pump head on the
2.Lubricate the pump hose with liquid detergent or petrogel. Start the rib of the hose in the slot of the pump head and push through. Tighten the three screws securely.
3.Slide the impeller on the shaft and securely tighten the square head screw on the flat of the shaft.
4.Connect the pump hose to the stainless steel and plastic fittings (see Figure 1 for proper con- nection).
5.Replace the back panel and the two phillips head
screws.PUMP
SWITCH
|
|
|
|
|
|
|
|
|
| White |
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
White |
| Black | Black |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LIQUID LEVEL |
| ||||||||
|
|
|
|
| ToProbes |
|
| CONTROL |
|
|
|
|
|
| ||
| PUMP |
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
| |||||||||||
|
|
|
| |||||||||||||
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
| Ground |
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| Black |
| Black | |||
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Stir Off /On
Switch
Figure 2. Electrical Wiring
C. Impeller Replacement
WARNING
DISCONNECT THE FREEZER FROM ELECTRICAL SUPPLY SOURCE BEFORE SERVICING!
1.Remove the two phillips head screws from the rear panel and pull the rear panel down and out.
2.Loosen the square head screw on the impeller and slide the impeller off the shaft.
3.Slide the replacement impeller on the shaft and securely tighten the square head screw on the flat of the shaft.
4.Replace the back panel and the two phillips head screws.
Impeller
Figure 3. Impeller
29