![](/images/backgrounds/89415/89415-3321x1.png)
SECTION 6
TROUBLESHOOTING
PROBLEM: |
| CAUSE | CORRECTION |
|
|
| |
High Pressure Cutout Switch Tripped. | Dirty condenser. | Clean condenser | |
|
|
|
|
Drive motor overload trips. | (Freezer | Improper Brix reading. | Refill with product that has Brix reading between 11 |
shuts down when running) |
|
| and 13. |
|
| ||
|
|
| |
Product dispenses incorrectly. | No mix in product cylinder or low mix in hopper. | Keep product cylinder and hopper full. | |
|
|
|
|
|
| Scraper blade missing from agitator. | Replace scraper blade. |
|
|
|
|
|
| Freezer is being overdrawn. | Slow down rate of draw. |
|
|
|
|
Product is too thin. |
| Ambient temperature is about 100°F (37.7°C). | Move or direct hot air away from freezer. |
|
|
|
|
|
| Freezer is being overdrawn. | Slow down the rate of draw. |
|
|
|
|
|
| Condenser is dirty. | Clean condenser. |
|
|
|
|
Agitator Does Not Rotate |
| Drive motor overload tripped off. | Turn freezer off for 5 minutes, allow automatic reset. |
|
|
|
|
|
| Agitator stuck or frozen. | Check for locked or bent fingers. Thaw product in |
|
|
| freezer if frozen. |
|
|
|
|
|
| No power to drive motor. | Check wire harness and switches in drive circuit and |
|
|
| repair or replace. |
|
|
|
|
|
| Drive motor is defective. | Check and replace if necessary. |
|
|
|
|
Toggle Switch in Standby |
| Toggle switch in OFF or CLEAN position. | Place toggle switch in ON position. |
|
|
| |
No Ice Crystals on Initial Freeze Down | Blown fuse in building or no input power to | Check for blown fuse or input power to freezer. | |
|
| freezer. |
|
|
|
|
|
|
| Mix too rich. | Take "Brix" reading. Fill with properly mixed product. |
|
|
|
|
|
| Restricted air flow to freezer. | Air enters lower front and discharges out the top back, |
|
|
| make certain both areas are clear. |
|
|
|
|
|
| Consistency set for too thin a product. | Set consistency to a thicker product. |
|
|
|
|
Spigot Leaking or Stuck. |
| Spigot "O" rings defective or missing. | Drain mix to below spigot level. Remove spigot, clean, |
|
|
| replace "O" rings as needed, lubricate and install. |
|
|
|
|
|
| Dried mix in spigot assembly. | Drain mix to below spigot level. Remove spigot retainer |
|
|
| and spigot. Disassemble and clean with hot water and |
|
|
| brush. Lubricate, |
|
|
| mix. |
|
|
|
|
13