5
INSTALLATION SPECIFICATIONS
The PRO48 can be used free-standing or
installed as a standard or flush built-in applica-
tion. For standard built-in installations, the face
frame of the unit will extend 2" (51) beyond
cabinetry. In flush built-in installations, the
front of the face frame will be flush with
surrounding cabinetry.
For built-in installations, make sure that the
finished rough opening where the unit is to be
installed is properly prepared. Refer to the
Installation Specifications illustration to be
sure that the rough opening dimensions, elec-
trical service and plumbing are correct.
7"
(178)
6"
(152)
ROUGH
OPENING DEPTH
24" (610)
STANDARD
26" (660)
FLUSH
ROUGH
OPENING WIDTH
471/2"(1206) STANDARD
48" (1219) FLUSH
E
3" (76)
6"
(152)
W
LOCATE WATER SUPPLY
WITHIN SHADED AREA
LOCATE ELECTRICAL
WITHIN SHADED AREA
53/16"
(132)
SHUT-OFF
VALVE
MIN 36" (914)
1/4"COPPER
WATER LINE
FRONT VIEW
TOP VIEW
ROUGH
OPENING HEIGHT
TOFINISHED
FLOORING
833/4"(2127)
STANDARD
841/8"(2137)
FLUSH
MIN HEIGHT
REQUIRED
TOFINISHED
FLOORING
(LEVELERS IN)
831/2"(2121)
STANDARD
833/4"(2127)
FLUSH
751/2"
(1918)
MODELS 648PROAND 648PROG
Rough Opening Width
(standard installation) 471/2"(1206)
Rough Opening Width
(flush installation) 48" (1219)
Rough Opening Height
(standard installation) 833/4"(2127)
Rough Opening Height
(flush installation) 841/8"(2137)
Minimum Height Required
(to finished flooring) 831/2"(2121)
Rough Opening Depth
(standardinstallation) 24" (610)
Rough Opening Depth
(flush installation) 26" (660)
Dimensions are for finished rough openings.
IMPORTANT NOTE:
To operate properly,
doors must be able to open a minimum of 90˚.
Use a filler strip in built-in corner installations
to assure a 90˚ door opening. Allow enough
clearance in front of the unit for full door
swing.
IMPORTANT NOTE:
Make sure that the floor
under the unit is level with the surrounding
finished floor and will be able to support the
weight of the unit—885 lbs (401 kg) or 900 lbs
(408 kg).
INSTALLATIONSPECIFIC ATIONS
Standardor flush installation for Models 648PRO and 648PROG.
PRO 48 INSTALLATION SPECIFICATIONS