10

10.5 Defective Disk Board

The disk board is hot-pluggable.

Begin

INDICATION

TEST/PROCEDURE

REFERENCE

 

System error message or

 

 

 

LED code identifies a

 

 

 

specific board

 

 

 

 

Locate indicated board.

 

 

 

 

 

 

Check LEDs on board to verify ASR

LED code must be Off-On-Off. See

 

 

has deactivated the board.

Table 9-2.

 

 

Set the SCSI IDs of the

See Appendix C, “SCSI Devices.”

 

 

replacement drives.

 

 

 

Replace the board or device.

 

 

 

Board is not active until system is

See Section 3.3, “Hot-Plug Feature.”

 

 

booted.

 

 

Board not identified or

 

 

 

intermittent problem

 

 

 

 

Check /var/adm/messages

 

 

 

 

 

 

Locate defective SCSI device with

 

 

 

probe-scsi-all (OpenBoot

 

 

 

command).

Section C.2, “Disk Board Target IDs.”

 

 

Check ID jumpers on board

 

 

 

 

 

End

Figure 10-5Diagnosing Disk Board Problems

10-6

Ultra Enterprise 6000/5000/4000 Systems ManualNovember 1996

Page 180
Image 180
Sun Microsystems 6.0005E+11 manual Defective Disk Board, Disk board is hot-pluggable