Connecting the Insolation and

Temperature Sensor

The optional insolation sensor (type Si-01TC-T by Ing.-Büro Mencke & Tegt- meyer) with its integrated PT-100 tempera- ture probe for measuring the temperature lets you record the insolation data and the corresponding module temperature and store them in the internal data memory as a 15-minute average value.

This additional measuring unit helps you analyse the performance of the system. Based on the values, any faults in the PV generator, e. g. shaded or defect solar cells, can be detected.

Prior to connecting an insolation sensor, move the cover of the Solar Inverter up, and fix it in position by tightening a late- ral screw. Please note that the inlets and outlets are not short-circuit-proof. Please observe chapter 2.1 «Safety Instructions».

The optional insolation sensor with the temperature probe is connected to the cable terminal block «X4» in the lower section of the circuit board.

Illustr.: Connection insolation sensor

120

Page 36
Image 36
Sunway NT 10000 user manual Connecting the Insolation Temperature Sensor