3-91

E-MEM Menu

GPI and PBUS TRIGGERS Menu

From the E-MEM Menu, press the KF TRIGGERS> button to

display the GPI and PBUS Triggers Menu. This menu is used to

attach GPI triggers or peripheral triggers to E-MEM registers so

that the triggers will fire when the registers are recalled. The

triggers may be tested after setting them up.

SELECT GPI — Selects the GPI Output (1 through 8) to which you

may attach an E-MEM recall trigger. The trigger numbers

correspond to the physical connections made to the GPI Output

connectors on the rear of the switcher frame.

ATTACH — Attaches the selected trigger to the indicated E-MEM

register ON, or turns the trigger OFF.

FIRE GPI — Test fire the selected (highlighted) GPI.
FIRE ATTACHED — Test fire all attached GPIs (set to ON)

simultaneously, regardless of what is currently selected.

Press exit to return to the E-MEM Menu.

GPI & PBUS TRIGGERS MENU
MISC
E-MEM / gpi & pbus triggers
ATTACH
PERIPH
SELECT
PERIPH ATTACH
GPI
SELECT
GPI FIRE
ATTACHED
FIRE
1
FIRE
ATTACHED
FIRE
A
B
C
D
E
F
G
H
DEVICE
-
-
-
-
-
-
-
FUNCTION
-
-
-
-
-
-
-
A
1
E-MEM LEVEL
-
-
-
-
-
-
-
-
PERIPHERAL TRIGGERS (PBUS 2)
-6A-
2
3
4
5
6
7
8
1
E-MEM LEVEL
-
-
-
-
-
-
-
-
GPI OUTPUT TRIGGERS
-6
1
OFF
MISC
1OFF
Effect: Keyframe: