Commands Listed in Alphabetical Order
Arguments TTL species a preset TTL high level of 1.4 V.
<NR3> is the clock level, in volts.
SEARCH:SEARCH<x>:TRIGger:A:SETHold:HOLDTime
Sets or returns the hold time setting for an setup/hold trigger search to determine
where to place a mark. <x> is the search number.
Group Search
Syntax SEARCH:SEARCH<x>:TRIGger:A:SETHold:HOLDTime <NR3>
SEARCH:SEARCH<x>:TRIGger:A:SETHold:HOLDTime?
Arguments <NR3> species the hold time setting in seconds. Positive values for hold time
occur after the clock edge. Negative values occur before the clock edge.
SEARCH:SEARCH<x>:TRIGger:A:SETHold:SETTime
Sets or returns the setup time setting for an setup/hold trigger search to determine
where to place a mark. <x> is the search number.
Group Search
Syntax SEARCH:SEARCH<x>:TRIGger:A:SETHold:SETTime <NR3>
SEARCH:SEARCH<x>:TRIGger:A:SETHold:SETTime?
Arguments <NR3> species the setup time for setup and hold violation triggering.
SEARCH:SEARCH<x>:TRIGger:A:SETHold:THReshold:CH<x>
Sets or returns the trigger search setup andholdlowerthresholdfortheselected
channel. This helps determine where to place search marks . Search<x> is the
search number, which is always 1. CH<x> is the channel number.
Conditions MSO oscilloscopes only.
Group Search
2-378 MSO4000 and DPO4000 Series Programmer Manual