Teledyne API - Model T200H/T200M Operation Manual Operating Instructions
93
4.7.2.8. RS-232 Report Function
The T200H/M DAS can automatically report data to the communications ports, where
they can be captured with a terminal emulation program or simply viewed by the user.
To enable automatic COM port reporting, follow the instruction shown in section 4.7.2.2
then press:
Edit Data Channel Menu
SETUP X.X 0) CONC: ATIMER, 8, 800
PREV NEXT INS DEL EDIT PRNT EXIT
Exits to the main
Data Acquisition
menu
SETUP X.X NAME:CONC
<SET SET> EDIT PRINT EXIT
SETUP X.X RS-232 REPORT: OFF
<SET SET> EDIT PRINT EXIT
ENTR acce pts the new
setting and returns to the
previous menu.
EXIT ignores the new setting
and returns to the previous
menu.
SETUP X. X RS-232 REPORT: OFF
OFF ENTR EXIT
Toggle bu tton to turn
reporting ON or OFF
Press SET> key until…
From the DATA ACQUISITION menu
(see Sectio n 6.7.2.2 )
4.7.2.9. Compact Report
When enabled, this option avoids unnecessary line breaks on all RS-232 reports. Instead
of reporting each parameter in one channel on a separate line, up to five parameters are
reported in one line, instead. For example, channel DIAG would report its record in two
lines (10 parameters) instead of 10 lines. Individual lines carry the same time stamp and
are labeled in sequence.
4.7.2.10. Starting Date
This option allows to specify a starting date for any given channel in case the user wants
to start data acquisition only after a certain time and date. If the Starting Date is in the
past, the DAS ignores this setting.
07270B DCN6512