TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM
Note: Before troubleshooting, be sure that the appliance main line gas
Important: Valve system troubleshooting should only be accomplished by a qualified service technician.
|
| SYMPTOM |
| POSSIBLE CAUSES |
|
|
|
|
| CORRECTIVE ACTION | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1. | Burner will not light. | A. Faulty Valve System. |
| See Below. |
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| B. Faulty limit switch. |
| Reset the limit switch button. If still not working, remove wire nut from the leads attached | |||||||||
|
|
|
|
|
|
|
|
| to the limit switch and check for continuity. If no continuity, replace limit switch. | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| C. “OFF/ON” or wall switch |
| Disconnect the two black wires from the wire nuts. Test switch(s) for continuity with | |||||||||
|
|
|
| defective. |
| a multimeter. If continuity is not indicated, switch(s) is defective and must be | ||||||||
|
|
|
|
|
|
|
|
| replaced. |
|
|
|
| |
|
|
|
|
|
|
|
|
| Note: Before replacing “OFF/ON” switch, be sure to check wiring for loose connec- | |||||
|
|
|
|
|
|
|
|
| tions or broken wires and repair as needed. | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
2. | Burners come “ON” but | A. Burner orifice plugged. |
| Check main burner orifice(s) for stoppage. Clean or replace. | ||||||||||
|
| go “OFF.” |
|
|
|
|
|
|
|
|
|
|
|
|
|
| B. Obstructed vent system. |
| Check vent system for obstructions. | ||||||||||
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| START |
|
|
|
|
|
|
|
|
|
| CHECK | ||
| • Turn Off Gas Supply |
|
|
| • Check For Proper Voltage At Control Harness |
| NO | • Line Voltage Power |
| |||||
| • Assure Valve Switch Is In ON Position |
|
|
| (See Insert A). Voltage Should Be 24V |
| • Low Voltage Transformer |
| ||||||
| • Disconnect Control Harness |
|
|
| Between Thermostat Or Pressure Switch |
|
|
| • Limit Controller |
| ||||
| • Set Thermostat To Call For Heat |
|
|
| And 24V Common And 24V Hot. | 2 |
|
|
| • Thermostat |
| |||
|
|
|
|
|
|
|
|
|
|
|
| • Wiring |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| YES |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| • Plug Control Harness Into Valve. Wait For |
|
|
|
|
| |||
|
|
|
|
|
| Internal Check Delay. |
|
|
|
|
|
|
|
|
|
|
|
|
| NO |
| • With Pilot Burner Cable Connected, Measure |
| NO |
| |||||
Insert A | End View Of |
| • Igniter Warms Up And Glows Red. |
|
|
| Voltage At Valve HSI Element Output. 24V |
|
|
|
| • Replace Valve. | |||||
|
|
|
|
|
|
| |||||||||||
|
| Control Harness |
|
|
|
|
|
|
| Nominal. (See Insert B) | 2 |
|
|
|
|
| |
|
| Connector |
|
|
|
|
|
|
| 1 |
|
|
|
|
| ||
| 24 Volt Hot |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 24 Volt |
|
|
|
|
|
|
|
| YES |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| Common |
|
| 1 | YES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| • Replace Igniter/Flame Rod Assembly. |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 24 Volt |
|
|
|
|
|
|
|
|
| YES |
|
|
|
|
|
|
| Switched |
|
|
|
|
| NO |
|
|
|
|
| NO |
| |||
Check For Damaged Or Missing Terminals |
| • Turn On Gas Supply. | • Pilot Burner Lights. |
| • Check That Pilot Gas Is Flowing. Wait To |
|
| • Replace Valve. | |||||||||
|
|
|
| Assure Plot Gas Tubing Is Purged. Recycle |
|
|
|
| |||||||||
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||
In Connector |
|
|
|
|
|
|
|
| Call For Heat If Necessary. |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| YES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| • Measure Voltage Between 24V Hot And 24V Common |
|
|
|
| ||||
|
|
|
|
|
|
|
|
| Leads To Valve Control. Must Measure At Least 19.5 | NO |
| ||||||
|
|
|
|
|
|
|
|
| VAC With Igniter Powered (See Insert A). To Identify | • Check Transformer And | |||||||
|
|
|
|
|
|
|
|
| |||||||||
| Insert B |
|
|
|
|
|
|
| Proper Lead, This Check Must Be Done With The |
|
|
| Line Volt Supply. | ||||
| Igniter Terminals |
|
|
|
| YES |
|
| Valve Control Connected And Igniter Powered. |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| YES |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| • Replace Pilot Assembly. |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| • Check That Pilot Flame Makes Good Contact With |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
| NO | Pilot Burner Flame Rod. |
|
|
|
|
|
| |||
|
|
|
| • Main Valve Opens And Main Burner Lights. | • Check For Good Electrical Connection Through The |
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
| Pilot Tubing. |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| • If Both Of The Above Are Good, Replace Igniter/Flame |
|
|
|
| ||||
|
|
|
|
|
| YES |
|
| Rod Assembly. |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| YES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| • System Is Okay. |
|
|
|
| • Cycle Thermostat Off And Back On. |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
1 | Igniter Will Cycle Off And Back On Once During |
| When Measured Voltage At Connections, Use |
|
|
|
|
| NO |
|
| ||||||
|
|
|
|
|
|
|
| ||||||||||
2 |
| • Main Burner Lights. |
|
|
| • Replace Valve. | |||||||||||
| The 90 Second Ignition Trial. All Voltage |
| Care To Assure Terminals Are Not Damaged. |
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
| ||||||||||
| Measurements Must Be Taken While The Igniter |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Is Powered. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|