SIT Millivolt Valve | Gas Control Knob | ||||
Spark Ignitor | Gas Control Knob | ||||
|
|
|
|
| O |
|
|
|
|
| N |
|
|
|
| LI | P |
|
|
|
|
| |
|
|
| O |
| |
|
|
| FFO T |
|
|
Honeywell Millivolt Valve
Figure 2
Manifold Pressure Port | ON/OFF Switch | ||
CONTROL | OFF ON | IN | Inlet |
REITNIG |
|
| Pressure |
|
| Port | |
|
|
| |
|
| PSI |
|
|
|
| Electronic |
|
|
| Gas Control |
|
|
| Valve |
|
| Honeywell Electronic | |
Figure 3 |
|
| Gas Valve |
If the appliance is not equipped with a wall switch or remote control, the main burner must be turned off and on with the gas control switch. Toggle the switch from ON to OFF to operate the main burner from ON to OFF.
2.When lit for the first time, this appliance will emit a slight odor for an hour or two. This is due to the
3.Keep lower control compartment clean by vacuuming or brushing at least twice a year. More frequent cleaning may be required due to excessive lint from carpeting, bedding materi- als, etc. It is important that control compart- ments, burners and circulating air passage-
ways of the appliance be kept clean.
Spark Ignitor
4.Always turn off gas to the pilot (millivolt appliances) before cleaning. Before
5.Always keep the appliance area clear and free from combustible materials, gasoline and other flammable liquids.
6.Remember, Millivolt appliances have a con- tinuous burning pilot flame. Exercise caution when using products with combustible vapors.
7.Clean the optional glass doors only when necessary. Wipe surface with clean, damp- ened, soft cloth. Follow with dry, soft towel as desired. Take care not to scratch the glass surface.
WARNING: DO NOT USE ABRASIVE CLEANERS. NEVER CLEAN THE GLASS WHEN IT IS HOT.
CAUTION: DO NOT ATTEMPT TO TOUCH THE DOORS WITH YOUR HANDS WHILE THE FIREPLACE IS IN USE. ALWAYS USE DOOR HANDLES. DOORS WILL BECOME VERY HOT WHEN FIREPLACE IS IN USE.
WARNING: FIREPLACES EQUIPPED WITH OPTIONAL ACCESSORY DOORS SHOULD BE OPERATED ONLY WITH THE DOORS FULLY OPEN OR FULLY CLOSED (FIGURE 4 ). THIS APPLI-
ANCE MAY ONLY BE FITTED WITH DOORS CERTIFIED FOR USE WITH THE APPLIANCE.
AVERTISSEMENT: POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE CERTIFIÊES AVEC L'APPAREIL.
Fully Open or
Fully Closed
Figure 4
COMBUSTION AIR CONTROLS
Many appliances are equipped when installed with an outside combustion air vent system that is designed to provide the appliance with outside
Combustion
Air Actuator
Figure 5
The actuator for combustion air system is standard on all appliances but must not be operated if the complete system is not in- stalled. Refer to Figures 5 and 6. When the complete outside combustion air vent system is installed, the installer will remove the actuator locking screw.
4 | NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. |