e-STUDIO3511/4511 TROUBLESHOOTING 5 - 94 November 2003 © TOSHIBA TEC
[2D30] Directory creation failure
[2D31] File creation failure
[2D33] File access failure
Check if the access privilege to the storage directory is writable.
Check if the server or local disk has a sufficient space in disk capacity.
[2D40] Image conversion abnormality
Turn the power OFF and then back ON. Perform the job in error again.
Replace the main memory and perform the job again.
If the error still occurs, first, check if there are no jobs existing and then initialize the shared folder
using the Setting Mode (08-667).
[2D62] File server connection error
Check the IP address or path of the server.
Check if the server is operating properly.
[2D63] Invalid network path
Check the network path.
If the path is correct, turn the power OFF and then back ON, and perform the job again.
[2D64] Login failure
Reset the login name and password. Perform the job.
Check if the account of the server is properly set up.
[2D65] Exceeding documents in folder: Creating new document is failed
Delete some documents in the folder.
[2D66] HDD full failure during processing
Reduce the number of pages of the job in error and perform the job again.
Check if the server or local disk has a sufficient space in disk capacity.