360050398

Table 10.8-4 Identify Information (Continued)

WORD

 

 

DESCRIPTION

Hex.

87

Command set/feature default

6023

 

15

0 (Fixed)

 

 

 

14

1 (Fixed)

 

 

 

13

1 (Fixed)

 

 

 

12-6

Reserved

 

 

 

5

1=General Purpose Logging feature set supported

 

 

4

Reserved

 

 

 

3

1=Media Card Pass Through Command feature set enabled

 

 

2

1=Madia serial number is valid

 

 

1

1=SMART self-test supported

 

 

 

 

 

88

15-8

Ultra DMA transfer mode selected

XX3F

 

7-0

Ultra DMA transfer modes supported

 

89

Time required for security erase unit completion

00XX

90

Time required for Enhanced Security erase completion

0000

91

Current Advanced Power Management setting

00XX

 

15-8 Reserved

 

 

 

7-0 Current Advanced Power Management setting set by Set Features

 

 

 

Command

 

 

92

Master Password Revision Code

XXXX

93

Hardware reset result. The conetnts of bits 12-0 of this word shall change only

XXXX

 

during the execution of a hardware reset.

 

 

15

0 (Fixed)

 

 

14

1 (Fixed)

 

 

13

1=device detected CBLID- above VIH

 

 

 

0=device detected CBLID- below VIL

 

 

12-8 Device 1 hardware reset result. Device 0 shall clear these bits to

 

 

 

zero.

 

 

 

 

Device 1 shall set these bits as follows :

 

 

 

12

Reserved.

 

 

 

11

0=Device 1 did not assert PDIAG-.

 

 

 

 

1=Device 1 asserted PDIAG-.

 

 

 

10-9 These bits indicate how Device 1 determined the device

 

 

 

 

number:

 

 

 

 

00=Reserved.

 

 

 

 

01=a jumper was used.

 

 

 

 

10=the CSEL signal was used.

 

 

 

 

11=some other method was used or the method is

 

 

 

 

unknown.

 

 

 

8

1 (Fixed)

 

 

7-0 Device 0 hardware reset result. Device 1 shall clear these bit to

 

 

 

zero.

 

 

 

 

Device 0 shall set these bills as follows:

 

 

 

7

Reserved.

 

 

 

6

0=Device 0 does not respond when Device 1 is selected.

 

 

 

 

1=Device 0 responds when Device 1 is selected.

 

 

 

5

0=Device 0 did not detect the assertion of DASP-.

 

 

 

 

1=Device 0 detected the assertion of DASP-.

 

 

 

4

0=Device 0 did not detect the assertion of PDIAG-.

 

 

 

 

1=Device 0 detected the assertion of PDIAG-.

 

 

 

3

0=Device 0 failed diagnostics.

 

 

 

 

1=Device 0 passed diagnostics.

 

 

 

2-1

These bits indicate how Device 0 determined the device

 

 

 

 

number:

 

 

 

 

00=Reserved.

 

 

 

 

01=a jumper was used.

 

 

 

 

10=the CSEL signa was used.

 

 

 

 

11=some other method was used or the method is

 

 

 

 

unknown.

 

 

 

0

1 (Fixed)

 

94

Current automatic acoustic management value

0000

 

15-8

Vendor’s recommended acoustic management value

 

 

7-0

Current automatic acoustic management value

 

95-99

Reserved

 

 

0000

100-103

Maximum user LBA for 48-bit Address feature set

XXXX

104-126

Reserved

 

 

0000

Toshiba Corporation Digital Media Network Company

Page 82 of 157

© 2005, Copyright TOSHIBA Corporation All Rights Reserved