When an Indicator is Lit or Flashing

The indicators on the projector’s control panel light or flash to notify of problems, as described below.

An indicator is also used to notify you of the currently set power mode. See “Power Cable Connections and Switching the Power On/Off” on page E-19.

STATUS indicator

STATUS

 

MENU

 

 

QUICK

 

MENU

STANDBY indicator

STANDBY

 

 

E

 

 

C

 

 

R

 

U

S

O

 

 

 

 

 

A

 

U

T

 

O

 

 

 

 

Indicator status

What you should do

 

 

 

STATUS

STANDBY When the power is on (Lit green)

It is time to replace the lamp.

 

 

Standby (Lit amber)

Replace with a new lamp cartridge.

 

 

Lit red

 

 

 

 

 

STATUS

STANDBY

 

The lamp has reached the end of its service life. The power

Flashing amber for 60 seconds, then lit

will no longer turn on.

 

 

 

 

The projector can be used for 100 hours after the lamp has reached

 

 

amber

 

 

the end of its service life.

 

 

 

 

 

Lit red

Replace with a new lamp cartridge.

 

 

 

 

 

 

 

STATUS

STANDBY

Lit red

The lamp cover is open.

 

 

 

 

Flashing red

The lamp cover is not properly mounted. Mount it properly.

 

 

 

 

 

(lit for 1 seconds/off for 1 seconds)

 

 

 

 

 

 

 

 

The temperature is abnormally high.

STATUS

STANDBY

 

• The temperature protector has been activated. If the room tem-

Lit red

perature is high, move the projector to a cool place. If the

 

 

 

 

 

projector’s internal temperature is high, check the cooling fan’s

 

 

Flashing red

ventilation slots and clean them if they are clogged.

 

 

(lit for 0.5 seconds/off for 0.5 seconds)

• When the temperature protector is activated, the power turns

 

 

 

off and in some cases will not turn back on immediately. In this

 

 

 

case wait about 90 seconds, then try again.

 

 

 

 

STATUS

STANDBY

 

The fan has stopped.

 

 

Lit amber

 

 

Unplug the power cable and contact a store that sells the TDP-P7

 

 

Flashing red

 

 

for repairs.

 

 

(lit for 0.5 seconds/off for 0.5 seconds)

 

 

 

 

 

STATUS

STANDBY

When the lamp has burned out dur-

The lamp will not light.

 

 

 

 

ing use

Wait at least 90 seconds, then turn the power back on. If the prob-

 

 

Flashing amber for 90 seconds, then lit

lem persists, unplug the power cord and contact a store that sells

 

 

amber

the TDP-P7 for repairs.

 

 

When the lamp does not come on

 

 

 

from the start

 

 

 

Lit amber

 

Flashing red

(lit for 1 seconds/off for 1 seconds)

Should an indicator be in a condition other than normal or flash at a rate other than the aforementioned, disconnect the power cable and contact your store of purchase.

Thermal Protector

When the temperature inside the projector becomes abnormally high, the STATUS indicator flashes red (0.5 seconds on/0.5 seconds off), the STANDBY indicator is a steady red, and at the same time the temperature protector operates and switches off the power of the projector.

Should this happen, please take the following actions.

1.Switch off the power and disconnect the power plug from the wall outlet.

2.Check the following matters and take the required measures.

When the projector is being used in a location that has a high ambient temperature, set it up again in a cool location. Check the outflow and intake holes and clean them if they are obstructed.

3.Wait about 60 minutes until the temperature of the projector drops.

If after having performed the above matters, the problem still has not been solved, please contact your store of purchase.