130

External Unit Setup

Installing SCSI device

(2) SCSI connector ( )

Used to connect the System Unit.

See “How to connect peripheral devices” on page 26.

Installing SCSI device

The installation of a SCSI device requires special knowledge or technology. If you have no experience in installing a SCSI device or require assistance, consult your authorized MAGNIA service provider.

Terminator

The SCSI bus is terminated at the SCSI controller and dedicated External Device Bay Unit Z1. Set the terminator of the installed SCSI device to disabled.

SCSI ID

The SCSI ID of the SCSI device to be installed is set so that it does not overlap with the SCSI ID of other devices installed.

The SCSI ID of the previously installed device is “5”.

When installing the second External Device Bay Unit Z1, change the SCSI ID in the procedure below.

Changing the SCSI ID

To change the SCSI ID follow the procedure described below, while referring to “Before starting operation” on page 48:

1If the server is running, shut it down and turn off the power.

NOTE: Installing the SCSI device while the power is on may damage the server and SCSI device.

2Disconnect the AC power cable.