TROUBLESHOOTING

! DANGER !

DO NOT service the unit until the main electrical power has been disconnected.

1.Unit does not operate (with drain pump; light on control board is not illuminated)

Cause

a.No electrical power to the unit.

b.Rocker switch set incorrectly.

c.Drain tube is kinked or obstructed.

d.Bad pump. Diagnose by bypassing the pump. Pull both pink wires from control board and jump the two terminals together. If unit starts up, then the pump is bad.

2.Unit does not operate (without drain pump; light on control board is not illuminated)

Cause

a. No power to unit.

3.Unit does not operate and light on control board is illuminated

Cause

a.Bad bin thermostat.

b.Bin thermostat set incorrectly.

4. No ice production

Remedy

a.Make sure unit is plugged in and outlet has power.

b.Check switch wiring. Set to “ICE.”

c.Clear the tubing. If water cannot drain from pump, unit will shut down due to safety design of pump.

d.Change pump. Jumping the two terminals together on the control board with a jumper wire will eliminate pump from the circuit.

Remedy

a. Jumper plug off power cord.

Remedy

a.Replace bin thermostat. The unit is falsely sensing a full bin.

b.Set bin thermostat at the 10:00 position.

Cause

 

Remedy

 

 

 

a.No water supplied to unit.

b.Stand pipe not inserted in water trough.

c.Re-circulating pump is defective.

a.Check that water is connected and turned on.

b.Insert stand pipe securely into water trough.

c.Replace re-circulating pump.

5.Low ice production

Cause

a.High ambient temperatures around unit.

b.Deposit build-up on evaporator grid.

c.Ice thickness dial set incorrectly.

d.Dirty condenser coil.

Remedy

a.Lower ice rate is normal with high ambient temperatures.

b.Run the unit through a clean cycle. Use only U-Line Ice Machine Cleaner.

c.Adjust ice thickness dial accordingly.

d.Clean condenser coil.