CO2075FF/2075RF & U-CO29FF MODELS

Design Features Performance

2

3

4

2

1

4

U-LINE1004

 

DISASSEMBLY PROCEDURES

Note: Échelon models do not require removal of the ice maker or freezer housing to access the fan motor, drain or evaporator.

To replace evaporator fan motor:

1.Disconnect unit from power source.

2.Remove 2 screws (1) from fan cover.

3.Remove 2 screws (2) holding fan bracket to liner.

4.Unplug fan connection.

5.Remove 2 nuts (3) holding the fan to the fan bracket.

6.Replace with new fan.

7.Plug in the fan connection.

8.Re-install fan bracket to liner making sure the fan wires are tucked behind the fan bracket.

9.Re-install unit and test.

To access evaporator or drain:

1.Disconnect unit from power source.

2.Remove 2 screws (1) from fan cover.

3.Remove 3 screws (4) from evaporator cover.

4.To remove, pull evaporator cover forward and turn.

26