EB-1 Electrical Box
The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the ab- sence of local codes, with the current CSA C22.1 Canadian Electrical Code.
For USA installations, follow the local codes and the national Electrical Code ANSI/NFPA No. 70.
It is strongly suggested that the wiring of the
Ensure that the power to the supply line has been disconnected before commenc- ing this procedure.
The
To connect the
1.Unscrew the retaining screw from the
2.Remove the front cover of the
3.Remove the plug socket assembly from the
4.Feed the supply line in from the outside through the cable clamp. (Fig. 9)
5.Connect black wire of the power supply line to the brass screw (polarized) of the socket assembly.
6.Connect the white wire of the power line to the chrome screw of the socket assembly.
7.Connect the ground wire of the supply line to the green screw of the socket assembly.
8.Refit the socket assembly back into the electrical box and replace the cover plate. Secure the cable with the clamp on the outside of the unit to prevent strain on the connections.
9.The
ply power to the FK12 or FK24 fan kits if fitted.
INSIDE
Electrical Box
FRONT OF UNIT
OUTSIDE
| OF | UNIT | FP580 |
FRONT |
| ||
|
|
Fig. 9
20010667
DV360/580 Series Direct Vent Gas Fireplace
Electronic Gas Control Valve
This appliance may be fitted with a Honeywell igni- tion module.
Installation of the remote on/off switch on electron- ic ignition units.
1.Thread the wiring through the holes on the side panels of the appliance. Take care not to cut the wire or insulation on metal edges. Route the wire to a conveniently located receptacle box.
2.Attach the wire to the ON/OFF switch and install the switch into the receptacle box.
3.Connect the white wire from the wall switch to the black wire from the transformer, using an approved wire nut. Connect the black wire from the wall switch to the black wire running from the #6 position of the ignition module, also using an approved wire nut.
|
| PILOT |
|
|
|
| |
|
|
| HONEYWELL IGNITION MODULE |
| |||
| MV | MV/VP | PV | 24V | 24V | SENSE | SPARK |
| GRD | ||||||
| 1 | 2 | 3 | 5 | 6 | 8 | 9 |
| BLACK |
|
|
|
|
|
|
| WHITE | WHITE |
|
|
|
| |
|
|
|
|
|
|
| |
|
|
| LO |
|
|
|
|
|
|
| HI |
|
|
|
|
|
|
| NOVA SIT 822 VALVE |
|
| BLACK | |
| WHITE |
|
|
|
|
| |
| POWER CORD |
|
|
|
|
|
|
W/FEMALE SPADE |
|
|
|
|
|
| |
| 120 VAC RTN | 24 VAC HOT |
|
|
| BLACK | |
|
|
|
|
|
|
| |
| WHITE |
| BLACK |
|
|
| OFF |
|
|
| WHITE |
|
|
| WHITE |
| BLACK |
|
|
|
|
| |
GREEN |
|
|
|
|
|
| |
| 120 VAC HOT | 24 VAC RET |
|
|
|
| |
| 40VA TRANSFORMER |
|
|
|
| WALL SWITCH | |
|
|
| BLACK | WHITE | |||
|
|
|
|
| |||
|
|
|
|
|
|
| FP1225 |
Fig. 10 | Honeywell ignition module. |
|
|
| |||
|
|
|
|
|
|
| 9 |