VHX SERIES STEAMER - TROUBLESHOOTING

SYMPTOM

 

POSSIBLE CAUSES

 

 

 

Steamer on, boiler will not heat. Reset

1.

Reset switch malfunction.

switch activated, low water light and high

2.

Water Level Control malfunction.

pressure light not lit, ready light lit.

3.

Cycling pressure switch out of adjustment or malfunction.

 

 

4.

High limit pressure switch out of adjustment or malfunction.

 

5.

K3, K4 relays malfunction.

 

6.

Relay board malfunction.

 

7.

Contactor(s) malfunction.

 

8.

Interconnecting wiring malfunction.

 

 

 

Pressure relief valve opening or leaking.

1.

Pressure relief valve malfunction.

 

2.

Cycling pressure switch out of adjustment or malfunction.

 

3.

High limit pressure switch out of adjustment or malfunction.

 

 

 

Steam output low or slow cooking.

1.

Cooking Compartments.

 

 

A. Blocked steam injector ports. Open door, press door switch

 

 

button and verify good steam flow into compartment.

 

 

B. Steam solenoid valve clogged or malfunction.

 

 

C. Steam intake shut-off valve not adjusted properly.

 

2.

Boiler Base.

 

 

A. Cycling pressure switch out of adjustment or malfunction.

 

 

B. Steam header line (supply) blockage.

 

 

C. Excessive amount of water in condensate tube loop from

 

 

boiler to pressure controls.

 

 

D. Pressure relief valve leaking.

 

 

E. Excessive steam supply line leaks.

 

 

 

Steamer leaks water.

1.

Water, steam or drain line connections loose (top or base).

 

2.

Heating element gasket not sealing.

 

3.

Heating element mounting plate not sealing.

 

4.

Gauge glass fittings loose.

 

 

 

Boiler water level too high, more than 1"

1.

Boiler fill valve malfunction.

visible in sight glass.

2.

Water level probes not wired correctly.

 

3.

Lime scale build-up on HL probe.

 

4.

Water level control malfunction.

 

 

 

Boiler does not fill or is slow to fill.

1.

Boiler fill water off or filtering system clogged.

 

2.

Manual blowdown valve on water level probe housing open.

 

3.

Boiler fill valve not receiving power, clogged or malfunction.

 

4.

Boiler blowdown/drain valve clogged and not fully closing.

 

5.

Air equalization tubes clogged.

 

6.

Water level control malfunction.

 

 

 

F25154 (February 2004)

 

Page 44 of 48

 

Page 44
Image 44
Vulcan-Hart ML-126852, ML-126857, ML-126853, VHX24E5, MHB24E Vhx Series Steamer - Troubleshooting, Symptom, Possible Causes