Operating Instructions
3.Move the throttle 1/4 to 1/2 open (toward FAST) and turn the ignition switch to the START position to start the engine. Release the key to the RUN position as soon as the engine starts.
IMPORTANT: If the engine fails to start after approximately 10 seconds of cranking, the engine should be checked before further crank- ing. Turn the key to the OFF position and allow a 60 second
TROUBLESHOOTING NOTE: If the engine cranks but does not start, check the following:
•The fuel valve solenoid is operating. Look at the exhaust pipe when cranking the engine - no smoke indicates no fuel is reaching the cylinder. If the solenoid is not operating, refer to CHECK- ING/SERVICING the Fuel Valve Solenoid in
Maintenance Instructions.
•The glow plugs are operating. Look at the exhaust pipe when cranking the engine - white smoke indicates improper glow plug operation and inadequate preheat. Consult the Kubota Workshop Manual to check glow plug function.
4.After the engine starts, make sure the oil pressure light goes off. If not, stop the engine immediately and find the cause of the problem. Make sure the oil pressure light is off prior to engaging the mower blades and beginning operation.
32