7
Closet installation - Dryer only
Recessed or closet installation - Dryer on pedestal

Minimum installation spacing for cabinet installation

The dimensions shown are for the minimum spacing allowed.
For cabinet installation, with a door, minimum ventilation
openings in the top of the cabinet are required.

Mobile home - Additional installation requirements

This dryer is suitable for mobile home installations. The install-
ation must conform to the Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal
Standard for Mobile Home Construction and Safety, Title 24,
HUD Part 280) or Standard CAN/CSA-Z240 MH.
Mobile home installations require:
Metal exhaust system hardware which is available for
purchase from your dealer.
Mobile home Installation Kit Part Number 346764. See Tools
and Parts section for ordering information.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
ElectricalRequirements
120-Volt, 60-Hz., AC-only, 15- or 20-amp fused electrical
supply is required. (Time-delay fuse or circuit breaker is
recommended.) It is recommended that a separate circuit
serving only this dryer be provided.
A.Side view - closet or confined area
B.Closet door with vents
A.Recessed area
B.Side view - closet or confined area
AB
14" max.
(35.6 cm)
18" min.
(45.72 cm)
0"
(0 cm) 0"
(0 cm)
31½"
(80 cm)
48 in.
2
(310 cm
2
)
24 in.
2
(155 cm
2
)
3"
(7.6 cm)
3"
(7.6 cm)
AB
0"
(0 cm)
0"
(0 cm) 0"
(0 cm) 0"
(0 cm)
27"
(68.6 cm) 31½"
(80 cm)
18" min.
(45.72 cm)
14" max.
(35.6 cm)
7" (17.8 cm)
9"
(22.9 cm
)
7" (17.8 cm)
0"
(0 cm) 31¹₂"
(80.0 cm) 27"
(68.6 cm)
0"
(0 cm) 0"
(0 cm) 0"
(0 cm)
ElectricalShockHazard
Plugintoagrounded3prongoutlet.
Donotremovegroundprong.
Donotuseanadapter.
Donotuseanextensioncord.
Failuretofollowtheseinstructionscanresultindeath,
fire,orelectricalshock.
WARNING

GROUNDINGINSTRUCTIONS

SAVETHESEINSTRUCTIONS

Fora grounded, cord-connected dryer :
This dryer must be grounded.In the event of malfunction or
breakdown,grounding will reduce the risk of electr ic shock
byproviding a path of least resistance for electric current.
This dryer is equipped with a cord havingan equipment-
groundingconductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and groundedin accordance with all local codes
and ordinances.

WARNING:

Improper connection of the equipment-
groundingconductor can result in a r isk of electric shock.
Checkwith a qualified electrician or ser vice representative
or personnel if youare in doubt as to whether the dr yeris
properly grounded.Do not modify the plug provided with the
dryer:if it will not fit the outlet, have a proper outlet installed
bya qualified electrician.