8
ElectricalConnection
Power Supply Cord
1. Disconnect power.
2. Remove the hold-down screw and terminal block cover.
Direct Wire
3. Assemble a ³⁄₄" (1.9 cm) UL listed strain relief (UL marking on
strain relief) into the hole below the terminal block opening.
Tighten strain relief screws just enough to hold the two clamp
sections together. Put power supply cord through the strain
relief. The strain relief should have a tight fit with the dryer
cabinet and be in a horizontal position.
4. Now complete installation following instructions for your type
of electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
A. Neutral grounding wire (green/yellow)
B. External ground conductor screw
C. Center, silver-colored terminal block screw
D. Terminal block cover and hold-down screw
WARNING
FireHazard
UseanewULlisted30amppowersupplycord.
UseaULlistedstrainrelief.
Disconnectpowerbeforemakingelectricalconnections.
Connectneutralwire(whiteorcenterwire)tocenter
terminal(silver).
Groundwire(greenorbarewire)mustbeconnectedto
greengroundconnector.
Connectremaining2supplywirestoremaining
2terminals(gold).
Securelytightenallelectricalconnections.
Failuretodosocanresultindeath,fire,or
electricalshock.
A
B
CD
WARNING
FireHazard
Use10gaugesolidcopperwire.
UseaULlistedstrainrelief.
Disconnectpowerbeforemakingelectricalconnections.
Connectneutralwire(whiteorcenterwire)tocenter
terminal(silver).
Groundwire(greenorbarewire)mustbeconnectedto
greengroundconnector.
Connectremaining2supplywirestoremaining
2terminals(gold).
Securelytightenallelectricalconnections.
Failuretodosocanresultindeath,fire,or
electricalshock.