– 7 –
GAS CONNECTION
GAS DATA
MODEL
INPUT RATING MANIFOLD PRESSURE
Natural L. P. Gases
(Propane) Natural L. P. Gases
(Propane)
WKG
WKGD
WKGC
WKGX
WKGDX
WKGCX
44,000 BTU/hr 44,000 BTU/hr 3.5" W.C.
(0.87 kPa)
10" W.C.
(2.49 kPa)
Gas supply connections and any pipe joint compound must be resistant to the action of propane gases.
Location of the gas inlet is at the rear of the oven. Codes require that a gas shutoff valve must be
installed in the gas line ahead of the oven.
Connect gas supply after leveling the oven. The gas supply line must be at least the equivalent of
34" (1.9 cm) iron pipe. Make sure the pipes are clean and free of obstructions, dirt, or pipe joint compound.
The ovens are equipped with fixed burner orifices which coincide with installation elevation.
The oven is provided with a regulator integral to the gas solenoid valve and requires no external
regulator.
Natural gas pressure regulators are preset for 3.5" W.C. (Water Column) (0.9 kPa); propane gas
pressure regulators are preset for 10" W.C. (2.5 kPa).
WARNING: PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS.
USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME.
After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.
TESTING THE GAS SUPPLY SYSTEM
When gas supply pressure exceeds 12 psig (3.45 kPa), the oven and its individual shutoff valve must be
disconnected from the gas supply piping system.
When gas supply pressure is 12 psig (3.45 kPa) or less, the oven should be isolated from the gas supply
system by closing its individual manual shutoff valve.
AIR ADJUSTMENT
Although main burner air is adjusted before shipment, it should be checked at the time of installation.
Excessive air will cause flames to lift off a burner when cold or may cause flash-back during normal
cycling of oven, particularly when propane gas is used.
Insufficient air will cause flames to burn with a yellow tip and result in carbon accumulation in the flame
chamber and heat exchanger tubes.
Contact your local Wolf Range servicer if required.