ACD1 Reference Manual 17
Panel operations
Port settings for an external controller
(“6. Network Setup” “IP Ctrl Port #”)
Here you can specify the port number that will be used to control the ACD1
from an external device such as an AMX or Crestron unit.
Here’s how to initialize the ACD1’s internal memory.
When you initialize the internal memory, the content that had been saved in memory (scenes for each amp, and ACD1
settings) will be lost.
Use caution when performing the following steps.
1. Power-off the ACD1.
2. While holding down the [BACK] button, turn the power on.
3. Press the [INC/YES] button to initialize the internal memory.
Do not turn off the power during the initialization process.
4. When initialization is completed, the ACD1 will automatically restart.
The log data is preserved even if you execute initialization.
Parameter Range Port number (hexadecimal)
Port No. 49153–50049 Specifies the ACD1’s port number. Change the port number if there are other devices
(other than the ACD1) that use the same port number.
Initializing the ACD1
å
IP Ctrl Port #
49153
CAUTION
Initialize
Are you sure?
CAUTION
NOTE