AE00222

Engine oil

cC

The generator has been shipped without engine oil. Do not start the engine before filling with the sufficient engine oil.

1.Place the generator on a level surface.

2.Remove the bolts 1, and then pull outward on the areas of rear cover 2 shown.

3.Remove the oil filler cap 3.

4.Fill the specified amount of the recommended engine oil, and then install and tighten the oil filler cap.

4Upper level

Recommended engine oil:

åYAMALUBE 4 (10W-30 or 10W-40),

SAE 10W-30 or 10W-40

SAE #30 ç SAE #20 ∂ SAE 10W

Recommended engine oil grade: API Service SE type or higher

Engine oil quantity:

1.3 L (1.14 US qt, 1.37 lmp qt)

0°C 25°C

åYAMALUBE 4 (10W-30 or 10W-40)

SAE 10W çSAE #20 SAE #30

32°F 80°F

5. Install the rear cover and tighten the bolts.